GaskiT
Accessories
Type selection
GaskiT Isolating Sleeves
Fields of application
Optimal electrical separation of flange connection bolts
Material
Mylar (spiral wound polyester film); standard version;
G-10 (epoxy resin bonded glass fabric); only for inch sizes;
G-11 (epoxy resin bonded glass fabric)
Properties
Designed for all common flange types; easy installation on site;
sleeve wall thickness 0.3 to 0.8 mm (depending on sizes and design);
temperature range Mylar: -60 °C up to +130 °C;
temperature range G10: -150 °C up to +150 °C;
temperature range G11: -150 °C up to +200 °C.
Sizes
For metric bolt sizes M12 to M52; for inch bolts ½" to 3½";
(other sizes on request).
GaskiT Isolating Washers
Fields of application
Optimal electrical separation of flange connection bolts
Material
G-10 (epoxy resin bonded glass fabric), standard version;
G-7 (silicone resin bonded glass fabric), on request;
Diamond Hyde™ (for VCFS Flange Isolation), standard version
Properties
Designed for all common flange types; easy installation on site; high compressive strength;
Temperature range G10: -60 °C up to +130 °C;
Temperature range G7: -60 °C up to +180 °C;
Temperature range Diamond Hyde™: -45 °C up to +218 °C
Sizes
For metric bolt sizes M12 to M52; for inch bolts ½" to 3½";
(other sizes on request).
GaskiT Steel Washers
Fields of application
In conjunction with isolation accessories for flange isolations
Material
Steel, galvanized (standard version); stainless steel A4 (special version)
Properties
Designed for all common flange types
Sizes
For metric bolt sizes M12 to M52; according to DIN 126 for steel versions and DIN 125 for stainless steel versions (other sizes on request).
GaskiT Isolation Bolt
Fields of application
Isolation/electrical separation of flange connection bolts
Material
Bolt materials: Grade 5.6, 8.8 CK35, 42 CrMo4,
UNC - Special materials on request;
Bolt isolation with epoxy resin glass fiber sheating, Including double steel and isolation washers; cured and reworked according to nominal sizes
Properties
Easy installation on site; optimal electrical separation;
extreme strength; no increase of bolt diameter;
operating temperature up to +200 °C (higher temperatures on request)
Sizes
Bolt dimensions in line with to DIN/ANSI flange requirements
(other sizes on request);
ND 25 - DN 300, PN 10 - PN 63