Telefonhörer

Multi utility house entry for the
installation of supply pipes

WalliN B

Builder Package

Type selection

4-fold
WalliN B

WalliN B Builder Package 4-fold - Floor

Fields of application
Multi utility house entry for supply lines (gas, water, electricity, telecommunication) for buildings without basement

Material
PVC housing, NBR sealing inserts, PVC FLS 90, TPE four-skid seal, metal frame

Properties
Gas- and water pressure-tight up to 1 bar; gas- and odor-tight (high-quality in terms of TA-Air); radon-tight; resistant to methane gas; four-skid seal: exterior sealing of concrete up to 10 bar

Sizes
Tube lengths: 3 m, 6 m, 9 m, 12 m
(Special sizes on request)

3-fold
WalliN B

WalliN B Builder Package 3-fold - Floor

Fields of application
Multi utility house entry for supply lines (gas, water, electricity, telecommunication) for buildings without basement

Material
PVC housing, NBR sealing inserts, PVC FLS 90, TPE four-skid seal, metal frame

Properties
Gas- and water pressure-tight up to 1 bar; gas- and odor-tight (high-quality in terms of TA-Air); radon-tight; resistant to methane gas; four-skid seal: exterior sealing of concrete up to 10 bar

Sizes
Tube lengths: 3 m, 6 m, 9 m, 12 m
(Special sizes on request)

2-fold
WalliN B

WalliN B Builder Package 2-fold - Floor

Fields of application
Multi utility house entry for supply lines (gas, water, electricity, telecommunication) for buildings without basement

Material
PVC housing, NBR sealing inserts, PVC FLS 90, TPE four-skid seal, metal frame

Properties
Gas- and water pressure-tight up to 1 bar; gas- and odor-tight (high-quality in terms of TA-Air); radon-tight; resistant to methane gas; four-skid seal: exterior sealing of concrete up to 10 bar

Sizes
Tube lengths: 3 m, 6 m, 9 m, 12 m
(Special sizes on request)

1-fold
WaliN B

WalliN B Builder Package 1-fold - Floor

Fields of application
Multi utility house entry for supply lines (gas, water, electricity, telecommunication) for buildings without basement

Material
PVC housing, NBR sealing inserts, PVC FLS 90, TPE four-skid seal, metal frame

Properties
Gas- and water pressure-tight up to 1 bar; gas- and odor-tight (high-quality in terms of TA-Air); radon-tight; resistant to methane gas; four-skid seal: exterior sealing of concrete up to 10 bar

Sizes
Tube lengths: 3 m, 6 m, 9 m, 12 m
(Special sizes on request)

 

Download

Product Information

Properties

  • Easy installation
  • Adjustable height of the base plate/screed
  • Flush-mount installation in the base plate

Fields of application

Secured and sealed multi utility house entry for supply lines like gas, water, electricity and telecommunication for buildings without basement.

Notes

Installation- and extension set are included in the scope of delivery. No need to pass on the installation set to other installers.

Description

The WalliN Multi Utility House Entry is the ideal solution for the gas- and water pressure-tight multiple entry of supply lines up to a pressure of 1 bar.

Thanks to the stable installation device and the visual check of the snap-on-socket, a simple assembly is possible, thereby avoiding installation errors. The flush-mount installation in the base plate prevents tripping hazards and wall damages. Furthermore, the scope of delivery includes a building period installation cover.

The roughened trowel flange allows for an easy integration of the vapour barrier foils. Height-adjustable base plate as well as floor screed.

The split end plugs are easy to install on the end of the casing pipe/tube.

Technical Information

Certificates

To offer our customers the best possible quality and service, we are organized according to DIN EN ISO 9001:2015 and have this continuously checked and certified.

CERTIFICATE ISO 9001:2015
This certification documents our conformity of the quality management system.

AEO-CERTIFICATE
Authorized Economic Operator "AEOC (customs simplification)"

  • DVGW-certified according to VP 601: overall system is gas- and water pressure tight up to 1 bar!
  • Gas- and odor-tight – high-quality in terms of TA-Air
  • Four-skid seal: exterior sealing of concrete up to 10 bar
  • WU-Richtlinie: Beanspruchungsklasse 1 + 2, DIN 18533 W1.1 -E